Polysilicon Production

CASE-2026-05

GUIZHOU

Medical Industry Purified Water System for Healthcare Production

The source document did not include embedded usable project photos. This module keeps the case page visual, flat and consistent without fabricating customer-site images.

DESIGN CAPACITY

2m³/h

OUTPUT RESISTIVITY

≤5.1 μS/cm

TOC AT POU

≤0.50 mg/L

Process

Pretreatment + Two-Stage RO + UV Sterilization + Microfiltration

UPW Skid Hall
Medical Purified Water
The source document did not include embedded usable project photos. This module keeps the case page visual, flat and consistent without fabricating customer-site images.

Project Fact Sheet

At a Glance

8 key data points

IndustryMedical Industry
LocationGUIZHOU
Capacity2 m³/h
ScopeFull Turnkey
ProcessPretreatment + Two-Stage RO + UV Sterilization + Microfiltration
Delivery30 Days
Commissioned2026-06
StatusNormal Operation


Case Description

Purified water support for medical production and device cleaning

The case content below is organized from the supplied Word document and kept focused on the disclosed medical industry project data.

Medical purified water is produced from raw water through multi-stage purification to remove impurities, heavy metals, microorganisms and other harmful contaminants. It is a foundational resource for medical services, pharmaceutical production and medical-device manufacturing, directly supporting water safety and process reliability.

This purified water system was customized according to user requirements. HONG JIE WATER used advanced RO and purified-water process design to meet production water needs, with a modular layout, compact footprint, simple operation, stable running and efficient energy use.

2m³/h purified water capacity
30dtotal project delivery
2026-06commissioned operation
Process Flow

Pretreatment + two-stage RO + UV sterilization + microfiltration

The process route is taken from the case sheet and arranged as a clear medical purified-water engineering sequence for the detail page.

01

Raw Water

Incoming raw water is pressurized and stabilized before pretreatment.

02

MMF

Multimedia filtration reduces suspended solids and turbidity before carbon filtration and softening.

03

ACF

Activated carbon filtration adsorbs residual chlorine and organic impurity load before softening and precision filtration.

04

Two-Stage RO

Two-stage reverse osmosis is used after pretreatment and pH adjustment to reduce ions and impurities for purified water production.

05

Purified Water Tank

Product water enters the purified water tank before distribution through the pure water pump.

06

UV + Microfilter

UV sterilization and microporous filtration provide final hygienic treatment before point-of-use supply.

07

Sampling & Monitoring

Sampling points and data monitoring support daily water-quality management and stable operation.

08

Stable Running

The system is recorded in the case sheet as operating normally after commissioning.

S 05 - Project Execution

On-site delivery, commissioning & acceptance

From process design to installation and commissioning, the project was organized around turnkey delivery and stable acceptance for medical purified-water use.

From turnkey engineering to stable operation: the project delivery is recorded as 30 days total, with commissioning in 2026-06. The gallery below presents the installation-site evidence structure listed in the Word document.

Water Quality Control

Control logic for medical purified water

Use the tabs to view the disclosed output indicators and the medical purified-water context from the supplied document.

Conductivity Target≤5.1 μS/cm

Conductivity is presented from the case hero metric and Chinese Pharmacopoeia 2020 requirements.

Conductivity, TOC and hygienic indicators

The case sheet lists core requirements from the Chinese Pharmacopoeia 2020: conductivity at 25 C not higher than 5.1 uS/cm, TOC not higher than 0.50 mg/L, aerobic microbial count not higher than 100 CFU/mL, endotoxin below 0.25 EU/mL and heavy metals not higher than 0.1 ug/mL.

2 m³/h design capacity ≤5.1 μS/cm conductivity metric ≤0.50 mg/L TOC target Stable purified water supply
Hygienic Control TargetHygienic Safety

The document highlights microbial, endotoxin and heavy-metal control as key medical purified-water requirements.

Microbial, endotoxin and heavy-metal limits

The supplied output field records aerobic microbial count not higher than 100 CFU/mL, endotoxin below 0.25 EU/mL and heavy metals not higher than 0.1 ug/mL, supporting water safety for medical production use.

Microbial count ≤100 CFU/mL Endotoxin <0.25 EU/mL Heavy metals ≤0.1 ug/mL Water safety monitoring
Industry RoleProduct Safety

Purified water is a core utility for medical production and device hygiene.

Why medical purified water matters

The document states that medical purified water is dedicated water that meets specific standards after multi-stage purification, and is essential for medical services, pharmaceutical production and medical-device manufacturing.

Supports device cleaning Supports hygienic processing Supports GMP/FDA requirements Protects medical water safety
Equipment Features

Technical highlights from the supplied medical project document

The feature cards below reorganize the equipment characteristics and technical advantages provided in the Word file for medical purified-water production.

Continuous Water Output

The purified-water equipment is designed for stable production water supply in medical and healthcare production environments.

No Acid-Base Regeneration

Advanced RO and purified-water process design supports stable water quality while simplifying operation and maintenance.

Unattended Operation

Humanized system design and water-quality data monitoring support easier management and daily operation.

Simple Installation

The supplied document highlights simple installation and convenient operation as part of the equipment advantage.

Full Turnkey Delivery

The project was delivered as a full turnkey scope from design and production to installation, commissioning and handover.

Two-Stage RO + UV + Microfilter

The process combines pretreatment, two-stage RO, UV sterilization and microporous filtration to meet medical purified-water requirements.

High-Standard Adaptability

Modular installation, compact footprint and convenient operation help the system fit medical production environments.

Normal Operation

The project status supplied in the case sheet is normal operation, after equipment fabrication, installation and commissioning.

Customer Voice

Acceptance feedback and customer endorsement

The Word document does not disclose a customer name or original quotation, so this section is written as anonymized acceptance feedback based on the supplied project facts.

“
The system supported medical purified-water production with stable water quality after commissioning, and the turnkey delivery matched the project start-up schedule.

Anonymous medical industry project feedback, summarized from the disclosed case facts: Guizhou, China location, 2 m³/h capacity, full turnkey delivery, 30-day delivery, 2026-06 commissioning and normal operation status.

Medical Industry Project GUIZHOU Normal Operation
Why It Builds Trust

Proof points visible to buyers

2 m³/h Matched purified-water demand

Designed for the disclosed 2 m3/h medical purified-water requirement.

30d Turnkey delivery cycle

Design, production, installation and commissioning were delivered within the case timeline.

≤5.1 μS/cm Clear water-quality target

Conductivity, TOC, microbial, endotoxin and heavy-metal targets are shown directly in the project indicators.

2026-06 Commissioned case

The project fact sheet records commissioning in June 2026.

Case Notes

Public-page handling for missing or optional source items

Click each note to expand. These notes are included to keep the published page faithful to the supplied case material.

No embedded image files were found in the Word package. The document lists image filenames and captions only, including project site, piping system and control cabinet notes. The page therefore uses a flat engineering visual rather than invented site photography.
The supplied document describes the project as a medical industry case and gives GUIZHOU as the project location. It does not disclose a customer company name, so the page does not add one.
The case sheet lists the process as raw water, booster pump, multimedia filter, activated carbon filter, softener, precision filter, first-stage RO, pH adjustment, intermediate tank, second-stage RO, purified water tank, pure water pump, UV sterilizer, microporous filter and point of use.
◆ READY TO START YOUR PROJECT

Building a similar UPW system?

Share your source water report — our process engineers will respond within 24 hours with a tailored process recommendation and reference projects matching your industry and capacity requirements.

Get a Quote

Thank you for your trust; we will respond to your enquiry within 24 hours.

No spam, only technical feedback
Response within 24 hours
Used by semiconductor, pharma & battery industries

Get Your Water Report → PFD in 24 Hours

Our engineers will analyze your water report and provide a tailored PFD solution.

No spam, only technical feedback
Response within 24 hours Used by semiconductor, pharma & battery industries