Phase 02 · PCB & IC Packaging Dual-Loop 1–18 MΩ·cm Routing

Printed Circuit Board (PCB)
Ultrapure Water Systems

Turnkey dual-grade pure and ultrapure water solutions tailored for High-Density Interconnect (HDI), IC substrate packaging, and precision electroplating baths. Eliminating chloride staining, ionic migration, and copper pad oxidation.

PCB Manufacturing Ultrapure Water System by Hongjie Water
DUAL-LOOP INTEGRATION

High-Density PCB & IC Substrate Skid

1–18MΩ·cm
DUAL-GRADE OUTPUT
Plating vs. final micro-etch rinse
0.00mg/L
TOTAL HARDNESS
Zero scaling in hot rinse tanks
< 0.1ppm
CHLORIDE IONS (CL⁻)
Zero galvanic pitting risk
5–50+m³/h
FLEXIBLE CAPACITY
Variable flow compensation
✦ PCB QUALITY PARAMETERS

Eliminating Plating Voids, Ionic Contamination & CAF Failures

In high-layer count PCB and mSAP (modified Semi-Additive Process) IC substrates with line/space under 25µm, residual ionic salts between copper traces create Conductive Anodic Filaments (CAF) and catastrophic field failures.

PCB Water Grade Performance

IPC-6012 & CPCA Standards
PROCESS STEPREQUIRED QUALITYSTANDARD ACHIEVED
Fine-Pitch HDI Final Clean≥ 15.0 – 18.0 MΩ·cmRO + EDI + Polishing MB
Acid Copper / Nickel / Gold Plating≥ 5.0 – 10.0 MΩ·cmRO + EDI Secondary Stage
Desmear & Etch-Back Rinse≥ 1.0 – 5.0 MΩ·cmTwo-Pass High-Rejection RO
Chloride (Cl⁻) & Sulfate< 0.1 ppm (Cl⁻ Zero)Prevents Micro-Etch Pitting
Total Dissolved Solids (TDS)< 0.1 mg/LConductivity < 0.1 µS/cm
Total Hardness (as CaCO₃)0.00 mg/L (Zero)Eliminates Nozzle Clogging

Dual-Pipeline Tiered Distribution

Rather than over-treating all factory water to 18 MΩ·cm, our dual-loop architecture separates general plating rinse water (Grade B: 5 MΩ·cm) from final solder mask and micro-via rinse lines (Grade A: 18 MΩ·cm), slashing plant operating expenses by up to 35%.

Dynamic Surge Absorption for Batch Dump Cycles

PCB plating rinse lines discharge and draw water erratically. Our integrated hydraulic surge buffers and multi-stage pressure regulators ensure constant nozzle spray pressure without cavitation.

Continuous Chemical-Free EDI Operation

By replacing hazardous conventional acid/base ion exchange regeneration with automated Continuous Electro-deionization (EDI), we ensure strict environmental compliance and continuous water quality.

✦ ENGINEERED PFD FLOW

Cost-Optimized Dual-Grade PCB Water Architecture

Reliable pre-filtration, high-rejection two-pass RO, and modular EDI polishing for complete factory coverage.

STAGE 01

Pretreatment & Softening

Removes raw city water silt, organics, and hardness to protect RO membranes.

  • Quartz Sand Multi-Media Filter
  • Granular Carbon Dechlorination
  • Automatic Dual Water Softener
  • 5 µm Cartridge Security Filter
STAGE 02

Two-Pass RO System

Desalinates 99%+ of salts and feeds primary plating wash lines.

  • Pass 1: Low-Energy Brackish RO
  • pH Adjustment Dosing Skid
  • Pass 2: High-Rejection Polyamide RO
  • Grade B Storage Buffer Tank (1–5 MΩ)
STAGE 03

EDI Module Polishing

Continuous demineralization boosting water quality to 15–18 MΩ·cm.

  • Industrial High-Recovery EDI Skid
  • 254nm In-line UV Disinfection
  • Nitrogen-Sealed UPW Buffer Tank
  • Online Thornton Resistivity Sensors
STAGE 04

Dual-Line Clean Distribution

Independent loops delivering appropriate purity to specific plating and etching cells.

  • Non-Regenerable Polish Mixed Bed (Opt.)
  • 0.2 µm Terminal Particle Filters
  • Clean-PVC / PVDF Distribution Loop
  • Variable Speed Pressure Booster Sets
✦ PCB WORKSHOP SCENARIOS

Targeted Solutions Across All Board Fabrication Operations

Providing the exact conductivity profile required for each wet process bench.

HDI Micro-Via Cleaning

Sub-micron particle and zero-hardness water penetrating high aspect-ratio blind and buried micro-vias after laser drilling and desmear.

IC Substrate & mSAP Lines

18 MΩ·cm ultrapure water for seed-layer etching, semi-additive plating, and ultra-fine pitch trace clean with zero ionic conductivity leakage.

Electroplating Bath Preparation

Consistent 5–10 MΩ·cm makeup water for Acid Copper, Electroless Nickel Immersion Gold (ENIG), and Immersion Silver baths without chemical interference.

SMT Stencil & PCBA Wash

Zero-residue spot-free rinse water removing solder paste flux, active rosins, and ionic contamination prior to conformal coating.

SMART PLANT ENGINEERING

Save up to 35% on Water Plant OPEX with Dual-Loop Architecture

By engineering multi-tier purity distribution headers tailored to specific plating versus final inspection requirements, Hongjie ensures optimal capital efficiency and lower power consumption.

Request Dual-Loop PCB Sizing Guide
Customized Grade Routing Directs RO water to pre-wash and 18 MΩ EDI water to final rinse lines.
Zero Nozzle Scaling 100% softened feed prevents calcium buildup in high-temperature spray bars.
Automated PLC Control One-touch auto backwash, chemical dosing regulation, and alarm diagnostics.
Compact Skid Footprint Engineered for tight factory floor spacing and easy maintenance access.
PCB WATER ENGINEERING CENTER

Configure Your PCB Water System

Submit your plant capacity, number of plating lines, and water quality requirements. Our engineering specialists will return an equipment sizing chart and budgetary estimate within 24 hours.

24h Rapid Response
Dual-Loop Savings
Complete Turnkey EPC

Request PCB Water System Proposal

Submit your parameters to receive a customized PFD flow diagram and quote.

Get a Quote

Thank you for your trust; we will respond to your enquiry within 24 hours.

No spam, only technical feedback
Response within 24 hours
Used by semiconductor, pharma & battery industries

Get Your Water Report → PFD in 24 Hours

Our engineers will analyze your water report and provide a tailored PFD solution.

No spam, only technical feedback
Response within 24 hours Used by semiconductor, pharma & battery industries