LFP Cathode Precursor Co-precipitation
Ca²⁺ > 3 ppb or Cl⁻ > 5 ppb in feed water forms CaCO₃ and FeOCl impurity phases — degrading first-cycle Coulombic efficiency and 500-cycle capacity retention.
Multi-stage RO + CEDI + 185 nm UV/TOC system engineered for lithium battery, hydrogen energy and new-energy material production lines. Modular, MES-ready, 24-hour unattended operation.
Six core technical parameters covering material, treatment range, output quality and operating economy — built for direct integration into MES-traceable battery and hydrogen production lines.
The Hongjie Water New Energy UPW system is built around a multi-stage architecture: 1st-stage RO → 2nd-stage RO → Continuous Electrodeionization (CEDI) → 185 nm UV/TOC Photolysis. Under 25 °C feed conditions, it delivers stable ≥15 MΩ·cm ultrapure water, achieves ≥90 % system recovery, and consumes ≤0.75 kWh per ton.
Compared to traditional mixed-bed + degassing tower combinations, water consumption is reduced by 40 % and chemical reagent usage by 95 %. The fully modular design supports 24-hour unattended operation and reserves an MES interface to integrate directly with lithium battery and hydrogen energy production lines under GMP / IATF 16949 traceability frameworks.
Pre-fabricated, factory-tested skids accelerate site installation and minimize on-site engineering.
Reduces TOC to < 1 ppb — meeting the strictest specifications for cathode precursor and PEM electrolyzer feed water.
Reserved Modbus / OPC-UA interface for real-time data sync with GMP / IATF 16949 traceability systems.
CEDI eliminates regenerant-acid & caustic dosing — sharply lowering OPEX and environmental footprint.
Even ppb-level contamination in feed water can degrade battery cycle life, electrolyzer efficiency, and overall yield. Hongjie Water UPW is engineered to eliminate these risks at the source.
Ca²⁺ > 3 ppb or Cl⁻ > 5 ppb in feed water forms CaCO₃ and FeOCl impurity phases — degrading first-cycle Coulombic efficiency and 500-cycle capacity retention.
TOC > 2 ppb in process water decomposes into SiC nuclei at 700 °C — concentrating stress on silicon particle surfaces and increasing electrode swelling.
Conductivity > 0.055 µS/cm allows Na⁺ / Fe³⁺ to accumulate in the proton membrane — increasing membrane resistance and stack voltage, lowering system efficiency.
From raw feed water to ultrapure delivery — every stage is monitored, modular, and built for stable continuous output.
Complete datasheet covering output quality, system performance, materials, and operating conditions across three configuration grades.
| Parameter | Standard Grade | High Grade | Premium Grade |
|---|---|---|---|
| Resistivity (25 °C) | ≥10 µS/cm equiv. | ≥15 MΩ·cm | ≥18 MΩ·cm |
| Conductivity | ≤2 µS/cm | ≤0.067 µS/cm | ≤0.055 µS/cm |
| Total Organic Carbon (TOC) | <50 ppb | <5 ppb | <1 ppb |
| Ca²⁺ / Cl⁻ Trace | <10 ppb | <3 ppb | <1 ppb |
| Bacteria Total | <10 CFU/mL | <3 CFU/mL | <1 CFU/mL |
| Particles > 0.2 µm | ≤100 /mL | ≤10 /mL | ≤1 /mL |
| Recommended Application | Boiler / general industry | Lithium battery line | Hydrogen PEM / Si-C anode |
| Parameter | Small Skid | Medium Line | Large Plant |
|---|---|---|---|
| Capacity Range | 0.25–5 m³/h | 5–80 m³/h | 80–500 m³/h |
| System Recovery Rate | ≥75 % | ≥85 % | ≥90 % |
| Salt Rejection (1st RO) | ≥99.5 % | ≥99.7 % | ≥99.8 % |
| Energy Consumption | ≤1.2 kWh/t | ≤1.0 kWh/t | ≤0.75 kWh/t |
| Operating Cost (per ton) | 0.20–0.30 USD | 0.10–0.20 USD | 0.03–0.10 USD |
| Continuous Operation | 24 h unattended | 24 h unattended | 24 h unattended |
| MES Interface | Optional | Standard (Modbus) | Standard (OPC-UA) |
| Component | Standard Build | Hi-Spec Build | Notes |
|---|---|---|---|
| Wetted Material — Pretreatment | U-PVC | SS304 | Per feed water chemistry |
| Wetted Material — RO Skid | SS304 | SS316 | FDA-grade EPDM o-rings |
| Wetted Material — UPW Loop | SS316L EP | SS316L EP / PVDF | Electropolished, Ra ≤ 0.4 µm |
| RO Membrane | Dow / Toray BW | Dow / Toray LE | Brackish & low-energy variants |
| CEDI Module | Snowpure / IP-LXM | GE E-Cell | Continuous, regenerant-free |
| Control System | Siemens S7-1200 + HMI | Siemens S7-1500 + SCADA | Full PLC + MES integration |
| Feed Water Temperature | 5–35 °C (optimal 25 °C) | Heat exchanger optional | |
| Feed Water TDS | ≤2,000 mg/L | Higher TDS by special design | |
Beyond purification capability, every system is delivered with intelligent management, premium components, and full customization — turning UPW into a competitive advantage on the production floor.
Cloud SCADA with predictive maintenance & remote fault diagnostics — minimizes downtime and dispatches alerts before failure.
Dow / Toray membranes, Grundfos pumps, Siemens PLCs & FDA-grade SS316L pipework — guaranteed long-term performance.
Layouts, capacity, materials & control logic adjusted to your exact site — from compact lab skids to multi-line plant rooms.
−40 % water, −95 % chemicals, ≤ 0.75 kWh/t — a measurable ESG win on every line we deliver.
From raw feed water to ultrapure delivery — a fully integrated pretreatment, double-pass RO, EDI polishing and N₂-blanketed distribution loop. Hover over each unit to see its function.